The Laserfiche Server Automation service stops unexpectedly. When the service crashes, it creates a log file in the Server Automation installation folder. The dump file will contain an error involving an ACCESS_VIOLATION.
There is a hotfix available for Workflow Suite 7.0.x. The fix is an updated version of LFSO11.dll (version 7.0.1.10).
To update Workflow
- Stop the Laserfiche Server Automation service.
- Click Start, navigate to Control Panel, Administrative Tools, and select Services.
- Scroll down and select Laserfiche Server Automation.
- From the Action menu, click Stop.
- Click the following link to download a zip file containing LFSO11.dll (version 7.0.1.10).
Hotfix_SCR30391.zip
- Replace the LFSO11.dll located at "C:\Program Files\Common Files\Laserfiche\LFObjects" with the one included in the zip file.
- Register LFSO11.dll.
- Click Start and then click Run.
- In the Run dialog box, type the following and click OK to register LFSO11.dll:
regsvr32 "C:\Program Files\Common Files\Laserfiche\LFObjects\LFSO11.dll"
- Start the Laserfiche Server Automation service.
- Click Start, navigate to Control Panel, Administrative Tools, and select Services.
- Scroll down and select Laserfiche Server Automation.
- From the Action menu, click Start.