Subsequent Optical Mark Recognition Processes Always Return False when a Previous Process Uses an Alignment Option.

February 19, 2007 | KB: 1011753
Quick Fields 7.1.2

Summary

A session with multiple Optical Mark Recognition processes will incorrectly process any subsequent Optical Mark Recognition processes that occur after one in which there is an alignment setting.

For example, in a session with three Optical Mark Recognition processes, if the first process is configured with an alignment setting, the second and third processes will always return false. If the second process is configured with an alignment setting, the third process will always return false.

Resolution

There is a hotfix available for Quick Fields 7.1.2. The fix is an updated version of LFMarkSense2.dll (version 7.1.2.1)

To update Quick Fields 7.1.2

  1. Close any open instances of Laserfiche Quick Fields.
  2. Click the following link to download a zip file containing an updated version of LFMarkSense2.dll.
    Hotfix_SCR29155.zip
  3. Replace your existing version of LFMarkSense2.dll located at "C:\Program Files\Common Files\Laserfiche\Batch Processor\LFMarkSense."
  4. Register the new LFMarkSense2.dll.
    1. Click Start and then click Run.
    2. Type the following and then click OK to register LFMarkSense2.dll.

      regsvr32 "C:\Program Files\Common Files\Laserfiche\Batch Processor\LFMarkSense\LFMarkSense2.dll"